1. Bulb(32x4p)=128W
2.Fan(85x3p)=255w
3.Tv(100wx1p)=100w
4.Freeze(450x1p)=450w
5.Oven(1000wx1p)=1000w
6.Others(300w)=300w
Total Load=2233w
For Single phase, (For Single Phase Q=1)
P=VICosQ
I=P/VcoseQ
=2233/230x1
=9.70Amp
Safety Factor
9.70+9.70x30percent
=12.61Amp or More 13 Amp cable you can use
Phase Voltage: Phase and Neutral Equal phase voltage
Line Voltage: Phase to phase voltage equal Line Voltage